Pump Star
| Chezpump | 12-17-2012 | comment profile send pm notify |
|
Any one with stroke limiter knowladge on a Pump Star please contact me 4196186968 |
||
| pumpkid | 12-17-2012 | reply profile send pm notify |
|
What is your issue? |
||
| Chezpump | 12-17-2012 | reply profile send pm notify |
|
stroke limited stuck wide open |
||
| pumpkid | 12-17-2012 | reply profile send pm notify |
|
on remote or hard wire |
||
| pumpkid | 12-17-2012 | reply profile send pm notify |
|
make sure you are in snale mode |
||
| Chezpump | 12-17-2012 | reply profile send pm notify |
|
Both Snale mode on Remote box? for boom? it does not work manuely as well |
||
| pumpkid | 12-17-2012 | reply profile send pm notify |
|
snale mode on remote will controle stroke |
||
| pumpkid | 12-17-2012 | reply profile send pm notify |
|
Do you have a wire digram? look at the conection in PWM box wire #3 and the relay R4 i have had to jump a ground from *12 to A1 A2 R4 |
||
| Chezpump | 12-17-2012 | reply profile send pm notify |
|
Thank you checking it now |
||
| pumpkid | 12-17-2012 | reply profile send pm notify |
|
let me know I can send you my wire digram if you need |
||
| Chezpump | 12-17-2012 | reply profile send pm notify |
|
Is there way to adjust manuly adjust at cyloind ? |
||
| Chezpump | 12-17-2012 | reply profile send pm notify |
|
That would be great and thank you stevec@irvingequipment.net
|
||