S tube not sliding clean
| Meister | 08-11-2014 | comment profile send pm notify |
|
Running a unique putz platform basically a BSA on a track. the Stube and spec plate heve been changed out and the S tube is binding as it switches over even when the Hex bolt at the back is loosened to hand tight. the weird thing is that the S tube only binds when being remotley stroked,not when it is stroked manually with the proportional joystick (manual) . any insite would be greatly appreciated. |
||
| b-alto | 08-12-2014 | reply profile send pm notify |
|
Pull the "S" tube grease bushings out and check i'll bet grout is in there. |
||















.jpg)
.gif)









.jpg)