| eugene | 05-18-2008 | comment profile send pm notify |
|
hey art the first mistake everyone does is let the hose scuff on the ground. i have a 2.5 inch 45 on the reducer with a 2X4 suport block. my first 3-4 foot of hose does not touch the ground ha ha |
||
| Bob | 05-18-2008 | reply profile send pm notify |
|
Good cover, Art. Keep you from having cranky mixer drivers |
||
| 79xlch | 05-19-2008 | reply profile send pm notify |
|
Art has balls, his hose does not scuff the ground. |
||
| 2IC | 05-20-2008 | reply profile send pm notify |
|
art, introduce me to a ballvalve pump, what and how does that chamber on the siamese work? |
||
| Big Tobacco | 05-20-2008 | reply profile send pm notify |
|
Here's a picture of a "transition cover" which is required on all BBCP pump trucks, from the smallest line pump up to our stationary hi-rise pumps. Unfortunately, I have seen one of these put to the test on more than 1 occasion. One day while pumping a deck on the 35-38th floor of a building, I blew the 6 to 5 reducer on a BP 8000. The transition cover deflected all of the slurry directly downward into the Eco-pan, away from the mixer drivers. If you note, the cover is designed to fit loosly around the rear end, enabling it to deflect any slurry, aggregate or debris away from anyone standing close to the pump. These are a real asset to safe pumping... Big T
|
||
| Bob | 05-20-2008 | reply profile send pm notify |
|
Those covers should be a required industry standard. They are life savers and injury preventers. IF the insurance industry had the first small clue about what is really dangerous on a pump (and they do not) they would make the use a condition of coverage. If your assend blew up without the protective cover, there would be no coverage. It is really funny when you think about it. 99% of the companies that write insurance policies for the pumping industry do not even know what they are insuring; or the risks involved. |
||
| Big Tobacco | 05-20-2008 | reply profile send pm notify |
|
Bob, Thanks for the feed back...I couldn't agree with you more! Several of the larger redi-mix suppliers in the Seattle area are refusing to back up to any pumps without transition covers on them! Needless to say, several other major players in our market are now "on board". If anyone is interested in finding out more about these covers, shoot me an email and I will get you the name and number of the manufacturer (it's not BBCP) here in Seattle. Big T |
||
| Bob | 05-20-2008 | reply profile send pm notify |
|
T how about posting the details ;~) |
||
| Big Tobacco | 05-20-2008 | reply profile send pm notify |
|
I'll get the info from the Safety Dept tomorrow Bob! Big T |
||
| Big Tobacco | 05-21-2008 | reply profile send pm notify |
|
As requested, here is the info concerning the transition covers developed by Brundage-Bone Concrete Pumping... Chris Perlatti
http://www.seattletarp.com/Concretetransitioncovers.asp Big T |
||
| wannadrag | 06-09-2008 | reply profile send pm notify |
|
Hello fellow concrete pumpers,I,ve ran an olin ball valve for 12 years,and used to set up as pictured.That is the only time I,ve blown a reducer.These days I always use a piece of 2 1/2 between the 3 to 2 1/2 and 2 1/2 to 2. Although the olin ball valve is one of the smoothest out there,it's been my experience that the hose tends to creep toward the direction of the pour,putting wear/strain on the two reducers. I do love the idea of having a wrap as added insurance,great idea! |
||