Cemex REALLY, come on doubled ended hose and ties operator to boom?
Todd 10-06-2010
comment profile send pm notify

Does anyone know if Cemex has a safety program? Do they belone to the ACPA or any other group?

http://video.concretepumping.com/videos/890/cemex-uses-double-end-hose-and-straps-operator-to-boom


52putz 10-06-2010
reply profile send pm notify

Hey, safety first.

What if the floor caved in?

:)


Many 10-06-2010
reply profile send pm notify

Does anyone know if Cemex has a safety program? Do they belone to the ACPA or any other group?

Guess not,geez


Todd 10-06-2010
reply profile send pm notify

Sw we should be strapping all hose men to the end of the boom??? what if he has a hose whip or the boom comes down?

Mr. Ed 10-06-2010
reply profile send pm notify

Actually, it's the hose-man tied to the boom, not the operator. No big deal UNTIL the boom is stretched flat out...then his weight causes a tip-over and he can't get away. I'm always amazed at the ingenuity of people in finding new and creative ways to get hurt.

Seed 10-06-2010
reply profile send pm notify

I think they are doing it wrong!


Dipstick 10-06-2010
reply profile send pm notify

what an idiots.

pink panther 10-06-2010
reply profile send pm notify

I wonder why the first half of that is in reverse. So, if the hose man works his way around the hose enough times, will he end up with the strap wrapped around the hose and not able to move.

Step Brother 10-07-2010
reply profile send pm notify

might be that he knows a hose whip could throw him off the deck that has NO guard rails. as bigstick used to always tell me, you cant fix stupid


mudcup 10-07-2010
reply profile send pm notify

What I never understand is why do all the videos I see of people pumping they always have the hose so high off the ground when I operate I keep the hose about a foot off of the ground at all times

oregonfan6285 10-08-2010
reply profile send pm notify

You run the hose high so the hose man doesn't have to push the entire hose.. if you run the hose a foot off the ground the hose man is pushing more weight. I don't like them pushing to much I would rather work the boom but people out here in Tennessee love pushing that hose.

mudcup 10-09-2010
reply profile send pm notify

I'll tell you in my opinion if the hose man has to push the hose around then the operator is not doing his job right,that's just what I think that's all.

Dipstick 10-09-2010
reply profile send pm notify

No pushing at the hose at all.. Wooowww you are a good operator. Or your finnishers have to work like hell or your floors don't have to be so flat.


mudcup 10-10-2010
reply profile send pm notify

Yes Dipstick your right I am a very good operator or so I'm told by the contractors but I guess they are full of $hit right

jeff_c2003 10-10-2010
reply profile send pm notify

Hose should be at hip height on slabs and knee height on walls and grade beams. pushing so much dead weight is hard on the body

oregonfan6285 10-11-2010
reply profile send pm notify

Mudcup a good operator would run the boom how the hose man would like. I always tell them this is your pump for the day I just run it. If its safe I will do the best I can

mudcup 10-13-2010
reply profile send pm notify

I understand what your saying guys after every mixer empty's out I always ask the hose guy how we're doin any they say very good they never say raise the hose but if they ever do I will, whatever makes it easier on the contractor I will do