Concord stroke stuck after one stroke
Trinity1 04-11-2022
comment profile send pm notify

We will start to pump but driver side hits the top of the stroke and stops. Any ideas where to stat trouble shooting would be greatly appreciated. 

bentley 04-15-2022
reply profile send pm notify

Proximity switches?

Pnw pumper 04-23-2022
reply profile send pm notify

Concords don’t have proximity switches

Pnw pumper 04-23-2022
reply profile send pm notify

If u take the pump out of pto then try and put it in 7th great and engage pto does it kill the engine or pressure out?? If so could b broken spring or orfice /set screw in logic valve 

LC 03-19-2023
reply profile send pm notify

Did you resolve the issue? Mines doing the same thing. 

concreteanimal 04-15-2023
reply profile send pm notify

Proximity switch?

GR1 04-21-2023
reply profile send pm notify

Chech valves on diff cylinders or shift block