cking | 02-01-2006 | comment profile send pm notify |
What kind of distance can you pour a line pour, and what should you watch out for. Using a reed pump truck. Thanks |
||
BrianABarone | 02-01-2006 | reply profile send pm notify |
There are many facts that are needed to answer your question. What size line are you using, what size Reed pump you have, mix design and slump, and is it all horizaontal or vertical or some of both. Give me some detials and I can help you with this question :) http://www.pumpoperators.com/brian/ I love to pump concrete. It is in my blood. I will do whatever it takes to do the job right and safely! Almost 20yrs under my belt and still learning. |
||
cking | 02-02-2006 | reply profile send pm notify |
Using a 36 meter reed pump, with a 4 line around a 5-6 inch slump. Using a 3/4 stone with a 25 mpa |
||
desertrat | 02-03-2006 | reply profile send pm notify |
oops reed pumpdesertrat |