We will have job this coming week and gona be the first time in our company to do this, Its a sea wall 300 yards of 5000 psi.with fiber concrete.They're discussing what is the best thing to do load the pump and the concrete trucks in the barge or we gonna do a line which is 1000plus feet long its a flat terrain.In my opinion if the barge can load the 30 concrete trucks of 10 yards each so be it, My question is will boom pumps can push that 5000 psi concrete in 1000feet line??.
|
||
Pump N00b | 05-13-2010 | reply profile send pm notify |
5000 psi is equal to 35 mpa wich means a B35 mix in my book. And 1000 + feet is 300 + meters. |
||
Vasa | 05-13-2010 | reply profile send pm notify |
Lots of retarder or ad water in the mixers on the barge , load some tanks with freshwater... |
||
pineos pumpin | 05-13-2010 | reply profile send pm notify |
i have pump through 750 ft of 5 inch line at a 160 slump with fiber and i didnt have any problems |
||
chongliyan | 05-13-2010 | reply profile send pm notify |
you mean you use boom pumps? were planning to use our putz 36m, if possible gotta be no mess were working on a resorts wherein a lot of guests, minimize noise etc..good thing for the line is we gonna control the truck interval. |
||
pump wrench | 05-14-2010 | reply profile send pm notify |
1000 ft. is nothing i have done that with a 900 schwing or an old 12 cell putz. My concern can the contractor move the material into the wall fast enough. Is the contractor going to jerk around turning the pump on and off good luck |
||
pump wrench | 05-14-2010 | reply profile send pm notify |
I notice you live where it gets alittle hot out. I have in some situations put sprinkler hoses on the pipe line to keep it cooler fro the sun beating on it. make sure your wear parts and cups are in good shape |