New 61m
Weave 03-10-2008
comment profile send pm notify

We're expecting a new 61m any words of advice, travel, setup time, washout?  What it will not tolerate?

Paint Master 03-10-2008
reply profile send pm notify

Weave what company do you work for?

Weave 03-11-2008
reply profile send pm notify

Champion Concrete Pumping in the Spokane CDA area

bigstick 03-11-2008
reply profile send pm notify

Operated one for over three years,  always use all the dunnage provided plus anything you can find.  Hopefull you will get the 25/25 pumpkit it will eat anything.  Plan on about 45 minutes to an hour to move because something that big  wont move fast.  Pump will bounce at first,  the key is to keep boom completely full of concrete and set-up with the boom leaning slightly towards the side your pumping.  Pump will run best when main section is almost vertical.  Keep changing the stroke limiter on remote box until you find the sweet spot, it will change with every job mix design etc.  Have any questions let me know.  Also ran 58 meter schwing for a while.  Just about the exact same pump.