Pump Star
Chezpump 12-17-2012
comment profile send pm notify

Any one with stroke limiter knowladge on a Pump Star please contact me 4196186968


pumpkid 12-17-2012
reply profile send pm notify

What is your issue?


Chezpump 12-17-2012
reply profile send pm notify

stroke limited stuck wide open


pumpkid 12-17-2012
reply profile send pm notify

on remote or hard wire


pumpkid 12-17-2012
reply profile send pm notify

make sure you are in snale mode


Chezpump 12-17-2012
reply profile send pm notify

Both Snale mode on Remote box? for boom? it does not work manuely as well


pumpkid 12-17-2012
reply profile send pm notify

snale mode on remote will controle stroke   


pumpkid 12-17-2012
reply profile send pm notify

Do you have a wire digram?     look at the conection in PWM box wire #3  and the relay R4   i have had to jump a ground  from *12 to A1 A2 R4


Chezpump 12-17-2012
reply profile send pm notify

Thank you checking it now


pumpkid 12-17-2012
reply profile send pm notify

let me know    I can send you my wire digram if you need


Chezpump 12-17-2012
reply profile send pm notify

Is there way to adjust manuly adjust at cyloind ?


Chezpump 12-17-2012
reply profile send pm notify

That would be great and thank you stevec@irvingequipment.net