Reed boom quit
concreteanimal | 07-26-2013 | comment profile send pm notify |
2006 reed boom pumped 30 yards today and pump just stopped then stroked a lick or two and stopped again. Was able to open a valve on top of valve block and manually stroke to suck ball to clean out it would cycle on one side and I would press valve at coil on other side. Gos to end of stroke and stops but doesn't pressure out. Changed coils, doesn't seem to be prox switch ( lights on prox illuminate ) I think it's electrical any suggestions. 3 1/2 hour drive to reed mechanic/ dealer |
||
putzman1975 | 07-26-2013 | reply profile send pm notify |
check dump valve |
||
bisley57 | 07-27-2013 | reply profile send pm notify |
Call Duane Remus at Reed |