schwing 2002 water pump electrical problem
Schwing31ht | 01-31-2014 | comment profile send pm notify |
on remote or local, water pump dosen't start. Light D8 have no power. Works manual so hydraulic are ok. Whats happen ? |
||
bisley57 | 01-31-2014 | reply profile send pm notify |
Does it have a low water sensor?If so twist the 2 wires together and see if it works electrically... |
||
xforce1 | 01-31-2014 | reply profile send pm notify |
I agree |
||
Schwing31ht | 01-31-2014 | reply profile send pm notify |
ya they have sensor i gonna try that or any suggestion relay ou ground ??? green light D8 turn on before pulsar coil or only when coil works properly ??? |
||
b-alto | 01-31-2014 | reply profile send pm notify |
Connect the two wires that go into the tank by the pump. Thats your low water relay. I had trouble with my 02 also. |
||
Schwing31ht | 01-31-2014 | reply profile send pm notify |
ok thanks guys and where is this relay ? |
||
gboom | 01-31-2014 | reply profile send pm notify |
No relais, just a sensor at the bottom of the water tank |