schwing 2002 water pump electrical problem
Schwing31ht 01-31-2014
comment profile send pm notify

on remote or local, water pump dosen't start. Light D8 have no power. Works manual so hydraulic are ok. Whats happen ?


bisley57 01-31-2014
reply profile send pm notify

Does it have a low water sensor?If so twist the 2 wires together and see if it works electrically...


xforce1 01-31-2014
reply profile send pm notify

I agree


Schwing31ht 01-31-2014
reply profile send pm notify

ya they have sensor i gonna try that   or any suggestion relay ou ground ??? green light D8 turn on before pulsar coil or only when coil works properly ???


b-alto 01-31-2014
reply profile send pm notify

Connect the two wires that go into the tank by the pump. Thats your low water relay. I had trouble with my 02 also.


Schwing31ht 01-31-2014
reply profile send pm notify

ok thanks guys and where is this relay ?


gboom 01-31-2014
reply profile send pm notify

No relais, just a sensor at the bottom of the water tank